SOS Technical Editor Hugh Robjohns replies:
These are both, strictly speaking, obsolete analogue metering formats! In short, the VU meter shows an averaged signal level and gives an impression of perceived loudness, while a PPM indicates something closer to the peak amplitude of the input signal. However, in our modern digital world, neither meter really performs adequately, and the current state of the art is enshrined in the new ITU-R BS1770 standard, which is being adopted very rapidly around the world in the broadcast sector and elsewhere. This is an excellent metering system that provides a new and very accurate Loudness Meter scaled in LUFS — which does a much better job than the VU — along with an oversampled True Peak Meter scaled in dBTP, which does a much better job than the PPM. I urge everyone to use these meters in preference to everything else!
However, for historians, the VU or Volume Unit meter
was conceived in 1939 and originally called the SVI or Standard Volume
Indicator. It was developed as a collaborative project by CBS, NBC and
Bell Labs in America and, since the meter scale was calibrated in
'volume units', that's the name that stuck! The SVI/VU meter is amongst
the simplest of all audio meter designs and essentially behaves as
a simple averaging voltmeter, with a moderate attack (or 'integration')
time of about 300ms. The needle fall-back time is roughly the same, and
the full meter specification is enshrined in the IEC 60268-17 (1990)
standard.
A VU meter's display is influenced by both the
amplitude and duration of the applied signal. With a steady sine-wave
signal applied to the input, a VU meter gives an accurate reading of the
RMS (root-mean-square, or average) signal voltage. However, with more
complex musical or speech signals the meter will typically under-read,
and a sustained sound will produce a significantly higher indication
than a brief transient signal, even if both have the same peak voltage.
In theory, a VU meter should respond to both the positive and negative
halves of the input audio signal, but the cheapest implementations
sometimes only measure one half of the waveform, and so can provide
different readings with asymmetrical signals compared to full VU meters.
The simplicity of the VU meter design makes it
relatively cheap to implement, and so VU meters tend to be employed in
equipment that requires a lot of meters — such as multitrack recorders
or mixers — or where accurate level indication is not essential.
The reference level indication is 0VU, but the audio
level required to achieve that could be whatever the user wished. The
original SVI implementation included an adjustable attenuator to
accommodate any standard operating level up to +24dBu (US broadcasters
still use nominal reference levels of +8dBu). Modern VU meters usually
omit the user-adjustable attenuator and are typically set to give a 0VU
indication for an input level of either 0dBu or +4dBu. The latter is the
most common 'pro standard', but a lot of manufacturers use the former
alignment, including Mackie. In general, then, the SVI or VU meter tends
to show the average signal voltage, and gives a reasonable indication
of perceived loudness.
The Peak Programme Meter or PPM is a much more
elaborate design and pre-dates the VU, as its development started in
1932, with the meter we know today appearing in 1938. Despite the name,
PPMs don't actually indicate the true peak of the signal voltage. Early
units employed a 10ms integration time (Type II meters), while later
units reduced the integration time to 4ms (Type I meters). These short
integration times were selected specifically to ignore the fastest
transient peaks, and as a result the PPM is often referred to as
a 'quasi-peak' meter to differentiate it from true-peak meters.
Typically, very brief transient signals will be under-read by about 4dB.
The reason for ignoring brief transients was to encourage operators to
set slightly higher levels than would otherwise be the case, on the
assumption that any transient overloads in recording or transmitting
equipment would be inaudible, which is generally the case for analogue
overloads of less than 1ms.
Whereas the VU meter has fairly equal attack and release times, the PPM is characterised by having a very slow fall-back time, taking over 1.5 seconds to fall back 20dB (the specifications vary slightly for Type I and II meters). The reasoning for the slow fall-back was to reduce eye-fatigue and make the peak indication easier to assimilate. The specifications of all types of PPM are detailed in IEC 60268-10 (1991), and the scale used by the BBC comprises the numbers 1-7 in white on a black background. There are 4dB between each mark, and PPM 4 is the reference level (0dBu). EBU, DIN and Nordic variants of the PPM exist with different scales. The EBU version replaces the BBC numbers with the equivalent dBu values, while both the Nordic and DIN versions accommodate a much wider dynamic range.